Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Appl Opt ; 63(6): 1618-1627, 2024 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-38437377

RESUMEN

We developed a broadband two-layer anti-reflection (AR) coating for use on a sapphire half-wave plate (HWP) and an alumina infrared (IR) filter for the cosmic microwave background (CMB) polarimetry. Measuring the faint CMB B-mode signals requires maximizing the number of photons reaching the detectors and minimizing spurious polarization due to reflection with an off-axis incident angle. Sapphire and alumina have high refractive indices of 3.1 and are highly reflective without an AR coating. This paper presents the design, fabrication, quality control, and measured performance of an AR coating using thermally sprayed mullite and Duroid 5880LZ. This technology enables large optical elements with diameters of 600 mm. We also present a thermography-based nondestructive quality control technique, which is key to assuring good adhesion and preventing delamination when thermal cycling. We demonstrate the average reflectance of about 2.6% (0.9%) for two observing bands centered at 90/150 (220/280) GHz. At room temperature, the average transmittance of a 105 mm square test sample at 220/280 GHz is 83%, and it will increase to 90% at 100 K, attributed to reduced absorption losses. Therefore, our developed layering technique has proved effective for 220/280 GHz applications, particularly in addressing dielectric loss concerns. This AR coating technology has been deployed in the cryogenic HWP and IR filters of the Simons Array and the Simons observatory experiments and applies to future experiments such as CMB-S4.

2.
Rev Sci Instrum ; 94(12)2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-38109472

RESUMEN

For cosmic microwave background (CMB) polarization observations, calibration of detector polarization angles is essential. We have developed a fully remote controlled calibration system with a sparse wire grid that reflects linearly polarized light along the wire direction. The new feature is a remote-controlled system for regular calibration, which has not been possible in sparse wire grid calibrators in past experiments. The remote control can be achieved by two electric linear actuators that load or unload the sparse wire grid into a position centered on the optical axis of a telescope between the calibration time and CMB observation. Furthermore, the sparse wire grid can be rotated by using a motor. A rotary encoder and a gravity sensor are installed on the sparse wire grid to monitor the wire direction. They allow us to achieve detector polarization angle calibration with an expected systematic error of 0.08°. The calibration system will be installed in small-aperture telescopes at Simons Observatory.

3.
Rev Sci Instrum ; 93(5): 055106, 2022 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-35649759

RESUMEN

We present the design and measured performance of a new carbon fiber strut design that is used in a cryogenically cooled truss for the Simons Observatory small aperture telescope. The truss consists of two aluminum 6061 rings separated by 24 struts. Each strut consists of a central carbon fiber tube fitted with two aluminum end caps. We tested the performance of the strut and truss by (i) cryogenically cycling and destructively pull-testing strut samples, (ii) non-destructively pull-testing the final truss, and (iii) measuring the thermal conductivity of the carbon fiber tubes. We found that the strut strength is limited by the mounting fasteners and the strut end caps, not the epoxy adhesive or the carbon fiber tube. This result is consistent with our numerical predictions. Our thermal measurements suggest that the conductive heat load through the struts (from 4 to 1 K) will be less than 1 mW. This strut design may be a promising candidate for use in other cryogenic support structures.

4.
J Environ Radioact ; 244-245: 106824, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35121278

RESUMEN

Both granular activated carbon (GAC) and silver mordenite (AgM) are utilized for the removal of contaminants and radionuclides (e.g., radioiodine) from off-gas streams in nuclear fuel reprocessing and high temperature immobilization of nuclear waste. Following their service lifetimes, the GAC and AgM contain an inventory of contaminants and radionuclides and require stabilization in a matrix for disposal. GAC and AgM are referred to as solid secondary waste (SSW) materials. Cementitious waste forms can be used as the stabilization matrix for SSW, however, for successful stabilization, the inclusion of GAC and AgM should not negatively impact the physical behavior of the cementitious waste form or increase release of the contaminants/radionuclides compared to the baseline case without stabilization. The present work focuses on evaluation of cement formulations, with and without slag, for the stabilization of iodine-loaded GAC or AgM. The results showed that both a slag-containing and slag-free formulations were able to stabilize GAC and AgM, up to 30 vol%, without deleterious impacts on the bulk physical properties of the encapsulating matrix. When monolithic samples of the GAC or AgM containing cement formulations were subjected to leach tests, it was observed that iodide leached from the SSW) had limited sorption to either of the cement matrices. Nonetheless, the iodine can interact with the SSW materials themselves. Specifically, iodine retention within monolithic samples containing the iodine-loaded GAC or AgM was improved for AgM containing waste forms while no improvement was observed for the GAC containing waste forms. The improvement for the AgM containing waste forms was likely due to an enrichment of Ag at the interface between the AgM particles and the cement matrix that can impede iodine migration out from the waste form. The results are significant in highlighting the potential for long-term retention of iodine in specific cementitious waste forms.


Asunto(s)
Yodo , Monitoreo de Radiación , Silicatos de Aluminio , Carbón Orgánico , Yoduros , Radioisótopos de Yodo , Plata
5.
Appl Opt ; 61(34): 10309-10319, 2022 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-36606797

RESUMEN

We present near-field radio holography measurements of the Simons Observatory Large Aperture Telescope Receiver optics. These measurements demonstrate that radio holography of complex millimeter-wave optical systems comprising cryogenic lenses, filters, and feed horns can provide detailed characterization of wave propagation before deployment. We used the measured amplitude and phase, at 4 K, of the receiver near-field beam pattern to predict two key performance parameters: 1) the amount of scattered light that will spill past the telescope to 300 K and 2) the beam pattern expected from the receiver when fielded on the telescope. These cryogenic measurements informed the removal of a filter, which led to improved optical efficiency and reduced sidelobes at the exit of the receiver. Holography measurements of this system suggest that the spilled power past the telescope mirrors will be less than 1%, and the main beam with its near sidelobes are consistent with the nominal telescope design. This is the first time such parameters have been confirmed in the lab prior to deployment of a new receiver. This approach is broadly applicable to millimeter and submillimeter instruments.

6.
Appl Opt ; 60(29): 9029-9035, 2021 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-34623982

RESUMEN

Near-field radio holography is a common method for measuring and aligning mirror surfaces for millimeter and sub-millimeter telescopes. In instruments with more than a single mirror, degeneracies arise in the holography measurement, requiring multiple measurements and new fitting methods. We present HoloSim-ML, a Python code for beam simulation and analysis of radio holography data from complex optical systems. This code uses machine learning to efficiently determine the position of hundreds of mirror adjusters on multiple mirrors with few micrometer accuracy. We apply this approach to the example of the Simons Observatory 6 m telescope.

7.
Nucleic Acids Res ; 48(11): 5907-5925, 2020 06 19.
Artículo en Inglés | MEDLINE | ID: mdl-32383760

RESUMEN

Mammalian antibody switch regions (∼1500 bp) are composed of a series of closely neighboring G4-capable sequences. Whereas numerous structural and genome-wide analyses of roles for minimal G4s in transcriptional regulation have been reported, Long G4-capable regions (LG4s)-like those at antibody switch regions-remain virtually unexplored. Using a novel computational approach we have identified 301 LG4s in the human genome and find LG4s prone to mutation and significantly associated with chromosomal rearrangements in malignancy. Strikingly, 217 LG4s overlap annotated enhancers, and we find the promoters regulated by these enhancers markedly enriched in G4-capable sequences suggesting G4s facilitate promoter-enhancer interactions. Finally, and much to our surprise, we also find single-stranded loops of minimal G4s within individual LG4 loci are frequently highly complementary to one another with 178 LG4 loci averaging >35 internal loop:loop complements of >8 bp. As such, we hypothesized (then experimentally confirmed) that G4 loops within individual LG4 loci directly basepair with one another (similar to characterized stem-loop kissing interactions) forming a hitherto undescribed, higher-order, G4-based secondary structure we term a 'G4 Kiss or G4K'. In conclusion, LG4s adopt novel, higher-order, composite G4 structures directly contributing to the inherent instability, regulatory capacity, and maintenance of these conspicuous genomic regions.


Asunto(s)
Elementos de Facilitación Genéticos , Genoma Humano , Guanina , Conformación de Ácido Nucleico , Emparejamiento Base , G-Cuádruplex , Reordenamiento Génico , Variación Genética , Genómica , Guanina/análisis , Humanos , Saccharomyces cerevisiae/genética , Duplicaciones Segmentarias en el Genoma , Eliminación de Secuencia
8.
Acta Crystallogr E Crystallogr Commun ; 75(Pt 9): 1291-1296, 2019 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-31523452

RESUMEN

A cadmium germanium arsenide compound, Cd3Ge2As4, was synthesized using a double-containment fused quartz ampoule method within a rocking furnace and a melt-quench technique. The crystal structure was determined from single-crystal X-ray diffraction (SC-XRD), scanning and transmission electron microscopies (i.e. SEM, STEM, and TEM), and selected area diffraction (SAD) and confirmed with electron backscatter diffraction (EBSD). The chemistry was verified with electron energy loss spectroscopy (EELS).

9.
BMC Mol Biol ; 13: 23, 2012 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-22747774

RESUMEN

BACKGROUND: Guanine quadruplex (G4 DNA) is a four-stranded structure that contributes to genome instability and site-specific recombination. G4 DNA folds from sequences containing tandemly repetitive guanines, sequence motifs that are found throughout prokaryote and eukaryote genomes. While some cellular activities have been identified with binding or processing G4 DNA, the factors and pathways governing G4 DNA metabolism are largely undefined. Highly conserved mismatch repair factors have emerged as potential G4-responding complexes because, in addition to initiating heteroduplex correction, the human homologs bind non-B form DNA with high affinity. Moreover, the MutS homologs across species have the capacity to recognize a diverse range of DNA pairing variations and damage, suggesting a conserved ability to bind non-B form DNA. RESULTS: Here, we asked if E. coli MutS and a heteroduplex recognition mutant, MutS F36A, were capable of recognizing and responding to G4 DNA structures. We find by mobility shift assay that E. coli MutS binds to G4 DNA with high affinity better than binding to G-T heteroduplexes. In the same assay, MutS F36A failed to recognize G-T mismatched oligonucleotides, as expected, but retained an ability to bind to G4 DNA. Association with G4 DNA by MutS is not likely to activate the mismatch repair pathway because nucleotide binding did not promote release of MutS or MutS F36A from G4 DNA as it does for heteroduplexes. G4 recognition activities occur under physiological conditions, and we find that M13 phage harboring G4-capable DNA poorly infected a MutS deficient strain of E. coli compared to M13mp18, suggesting functional roles for mismatch repair factors in the cellular response to unstable genomic elements. CONCLUSIONS: Taken together, our findings demonstrate that E. coli MutS has a binding activity specific for non-B form G4 DNA, but such binding appears independent of canonical heteroduplex repair activation.


Asunto(s)
Reparación de la Incompatibilidad de ADN/genética , ADN Bacteriano/metabolismo , Proteínas de Escherichia coli/metabolismo , Escherichia coli/enzimología , G-Cuádruplex , Proteína MutS de Unión a los Apareamientos Incorrectos del ADN/metabolismo , Ensayo de Cambio de Movilidad Electroforética , Proteínas de Escherichia coli/aislamiento & purificación , Estructura Molecular , Proteína MutS de Unión a los Apareamientos Incorrectos del ADN/aislamiento & purificación , Oligonucleótidos/genética , Especificidad de la Especie
10.
Appl Opt ; 48(19): 3614-25, 2009 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-19571916

RESUMEN

We study the performance of achromatic half-wave plates (AHWPs) as a function of the detection bandwidth of a power detector operating in the millimeter wave band and the spectral shape of the incident radiation. We focus particular attention on the extraction of the degree of incident polarization and its orientation angle from the intensity measured as a function of AHWP rotation angle, which we call the IVA (intensity versus angle). We describe the formalism to extract the two incident polarization parameters. We use this formalism to quantify the phase offset of the IVA and point to potential systematic errors in the extraction of this offset in cases where the incident spectrum is not sufficiently well known. We quantify the phase offset and modulation efficiency as a function of the relative angles between the plates in the stack and find that high modulation efficiency can be achieved with alignment accuracy of a few degrees. We present measurements of the spectral response of an AHWP made with five plates. The measurements predict a modulation efficiency that is higher than 98% for three bands centered at 150, 250, and 410 GHz.

11.
Anesth Analg ; 105(4): 1066-71, table of contents, 2007 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17898389

RESUMEN

BACKGROUND: Although propofol has not traditionally been considered a drug of abuse, subanesthetic doses may have an abuse potential. We used this survey to assess prevalence and outcome of propofol abuse in academic anesthesiology programs. METHODS: E-mail surveys were sent to the 126 academic anesthesiology training programs in the United States. RESULTS: The survey response rate was 100%. One or more incidents of propofol abuse or diversion in the past 10 yr were reported by 18% of departments. The observed incidence of propofol abuse was 10 per 10,000 anesthesia providers per decade, a fivefold increase from previous surveys of propofol abuse (P = 0.005). Of the 25 reported individuals abusing propofol, 7 died as a result of the propofol abuse (28%), 6 of whom were residents. There was no established system to control or monitor propofol as is done with opioids at 71% of programs. There was an association between lack of control of propofol (e.g., pharmacy accounting) at the time of abuse and incidence of abuse at the program (P = 0.048). CONCLUSIONS: Propofol abuse in academic anesthesiology likely has increased over the last 10 yr. Much of the mortality is in residents. Most programs have no pharmacy accounting or control of propofol stocks. This may be of concern, given that all programs reporting deaths from propofol abuse were centers in which there was no pharmacy accounting for the drug.


Asunto(s)
Centros Médicos Académicos , Anestesiología/estadística & datos numéricos , Internado y Residencia , Inhabilitación Médica/estadística & datos numéricos , Mala Conducta Profesional/estadística & datos numéricos , Propofol , Trastornos Relacionados con Sustancias/epidemiología , Anestesiología/educación , Recolección de Datos
12.
Am J Psychiatry ; 164(4 Suppl): 5-123, 2007 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-17569411
15.
Appl Opt ; 44(22): 4666-70, 2005 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-16075879

RESUMEN

We have constructed an achromatic half-wave plate (AHWP) suitable for the millimeter wavelength band. The AHWP was made from a stack of three sapphire a-cut birefringent plates with the opticalaxes of the middle plate rotated by 50.5 deg with respect to the aligned axes of the other plates. The measured modulation efficiency of the AHWP at 110 GHz was 96 +/- 1.5%. In contrast, the modulation efficiency of a single sapphire plate of the same thickness was 43 +/- 4%. Both results are in close agreement with theoretical predictions. The modulation efficiency of the AHWP was constant as a function of incidence angles between 0 and 15 deg. We discuss design parameters of an AHWP in the context of astrophysical broadband polarimetry at the millimeter wavelength band.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...